AGARD Working Group 21 Data Base, October 1997 CASE PCH02 Corrected rough wall pipe, Mean velocity profiles, Corrected law of the wall plot Re=200,000 yU*/nu U/U* 0.294450E+02 0.138817E+02 0.331722E+02 0.140615E+02 0.387630E+02 0.144220E+02 0.424903E+02 0.146362E+02 0.480811E+02 0.149434E+02 0.573991E+02 0.152935E+02 0.667171E+02 0.155813E+02 0.853532E+02 0.160668E+02 0.103989E+03 0.164850E+02 0.122625E+03 0.167980E+02 0.150579E+03 0.172347E+02 0.178534E+03 0.176308E+02 0.215806E+03 0.180640E+02 0.262396E+03 0.185701E+02 0.308986E+03 0.189356E+02 0.402166E+03 0.195658E+02 0.495347E+03 0.200848E+02 0.681708E+03 0.209052E+02 0.961249E+03 0.218251E+02 0.124079E+04 0.225273E+02 0.152033E+04 0.231376E+02 0.189305E+04 0.237677E+02 0.235895E+04 0.244321E+02 0.282486E+04 0.250478E+02 0.329076E+04 0.255156E+02 0.375666E+04 0.259016E+02 0.422256E+04 0.261550E+02 0.473971E+04 0.262505E+02