AGARD Working Group 21 data base - October 1997 CASE PCH02 Smooth Wall Pipe Reynolds Stresses Re =75,000 (nominal) Ut =0.4864 m/s x/D =398.5 D =99.1 mm nominal wire length =0.8 mm Hot-wire results corrected for density decrease at the measuring station owing to the pipe pressure drop. data in following order y(mm), y/(D/2), u'2/Ut2, v'2/Ut2, -u'v'/Ut2, 49.55 1.0000 0.7781 0.4581 0.0574 45.00 0.9082 0.8780 0.4658 0.1475 40.00 0.8073 1.138 0.5207 0.2652 35.00 0.7064 1.458 0.5887 0.3521 30.00 0.6054 1.886 0.6881 0.4759 25.00 0.5045 2.323 0.7616 0.5657 20.00 0.4036 2.771 0.8630 0.6972 15.00 0.3027 3.282 0.9442 0.8027 12.00 0.2422 3.619 0.9860 0.8877 10.00 0.2018 3.849 0.9956 0.9097 7.00 0.1413 4.096 1.042 0.9630 6.00 0.1211 4.243 1.044 0.9915 5.00 0.1009 4.349 1.053 0.9852 4.50 0.0908 4.473 1.072 1.028 4.00 0.0807 4.405 1.067 0.9873 3.50 0.0706 4.495 1.076 0.9784 3.00 0.0605 4.520 1.072 0.9873